Bug 6515

Summary: KDE System Monitor (ksysguard) does not allow more than 1 sensor in a display
Product: Mageia Reporter: Dennis Griffin <dennisgrif>
Component: RPM PackagesAssignee: John Balcaen <balcaen.john>
Status: RESOLVED FIXED QA Contact:
Severity: normal    
Priority: Normal Keywords: PATCH, UPSTREAM
Version: Cauldron   
Target Milestone: ---   
Hardware: x86_64   
OS: Linux   
URL: https://forums.mageia.org/en/viewtopic.php?f=7&t=2819&p=21232#p21232
Whiteboard:
Source RPM: kdebase4-workspace-4.8.4-1.mga3.src.rpm CVE:
Status comment:

Description Dennis Griffin 2012-06-20 04:08:40 CEST
Description of problem:
dragging multiple sensors onto a graph doesn't work

Version-Release number of selected component (if applicable):
4.8.4

How reproducible:
always

Steps to Reproduce:
1.click "New Tab"
2.Drag items from "Sensor Browser" to graph
3. Only the first sensor is used.

This was reported to kde.org see:

https://bugs.kde.org/show_bug.cgi?id=290504

A patch to fix was supplied on June 6, 2012

There is a workaround by editing the tab xml file.
Manuel Hiebel 2012-06-20 13:27:09 CEST

Keywords: (none) => PATCH, UPSTREAM
Assignee: bugsquad => balcaen.john

Comment 1 Manuel Hiebel 2012-08-11 13:34:51 CEST
fixed with kde 4.9

Status: NEW => RESOLVED
Resolution: (none) => FIXED