Bug 31280

Summary: plasmashell aborting due to incompatible Qt library after recent updates leaving just a black screen
Product: Mageia Reporter: Dave Hodgins <davidwhodgins>
Component: RPM PackagesAssignee: KDE maintainers <kde>
Status: RESOLVED FIXED QA Contact:
Severity: critical    
Priority: Normal CC: office, pfortin
Version: Cauldron   
Target Milestone: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Source RPM: plasma-workspace-5.26.3-2.mga9.src.rpm CVE:
Status comment:

Description Dave Hodgins 2022-12-14 07:40:02 CET
Dec 14 01:28:59 systemd[2809]: Starting plasma-plasmashell.service...
Dec 14 01:29:00 systemd[2809]: Started plasma-plasmashell.service.
Dec 14 01:29:00 plasmashell[13093]: kf.plasma.quick: Applet preload policy set to 1
Dec 14 01:29:00 plasmashell[13093]: qml: PlasmaExtras.ScrollArea is deprecated. Use PlasmaComponents3.ScrollView instead.
Dec 14 01:29:00 plasmashell[13093]: Cannot mix incompatible Qt library (5.15.6) with this library (5.15.7)
Dec 14 01:29:00 systemd[2809]: plasma-plasmashell.service: Main process exited, code=dumped, status=6/ABRT
Dec 14 01:29:00 systemd[2809]: plasma-plasmashell.service: Failed with result 'core-dump'.
Dec 14 01:29:01 systemd[2809]: plasma-plasmashell.service: Scheduled restart job, restart counter is at 5.
Dec 14 01:29:01 systemd[2809]: Stopped plasma-plasmashell.service.
Dec 14 01:29:01 systemd[2809]: plasma-plasmashell.service: Start request repeated too quickly.
Dec 14 01:29:01 systemd[2809]: plasma-plasmashell.service: Failed with result 'core-dump'.
Dec 14 01:29:01 systemd[2809]: Failed to start plasma-plasmashell.service.
Cristian Pîrîu 2022-12-14 07:53:17 CET

CC: (none) => office

Pierre Fortin 2022-12-14 08:31:31 CET

CC: (none) => pfortin

Comment 1 Dave Hodgins 2022-12-14 20:45:15 CET
Working after todays updates.

Resolution: (none) => FIXED
Status: NEW => RESOLVED