| Summary: | A temperature sensor is every times at 90 ° | ||
|---|---|---|---|
| Product: | Mageia | Reporter: | Jean-Louis CURCI <jlcurci> |
| Component: | RPM Packages | Assignee: | Kernel and Drivers maintainers <kernel> |
| Status: | RESOLVED OLD | QA Contact: | |
| Severity: | normal | ||
| Priority: | Normal | CC: | geiger.david68210, marja11, thierry.vignaud |
| Version: | 5 | Keywords: | NEEDINFO |
| Target Milestone: | --- | ||
| Hardware: | i586 | ||
| OS: | Linux | ||
| Whiteboard: | |||
| Source RPM: | kernel | CVE: | |
| Status comment: | |||
what is the output (in a konsole or terminal) of rpm -qa | grep kernel | grep latest and of rpm -qa | grep lm_sensors and please also attach lspcidrake.txt that is the result of lspcidrake -v > lspcidrake.txt Keywords:
(none) =>
NEEDINFO This is not an installer bug CC:
(none) =>
thierry.vignaud Mass-reassigning all bugs with "kernel" in the Source RPM field that are assigned to tmb, to the kernel packagers group, because tmb is currently MIA. Assignee:
tmb =>
kernel Hi Jean-Louis, Thank you for having taken the needed time to report this issue! Did this bug get fixed? If so, please change its status to RESOLVED - FIXED If it didn't, then we regret that we weren't able to fix it in Mageia 5. Mageia 5 has officially reached its End of Life on December 31st, 2017 https://blog.mageia.org/en/2017/11/07/mageia-5-eol-postponed/ It only continued to get important security updates since then, because we are waiting for a big Plasma5 update in Mageia 6, that'll fix many of the Mageia 5 => 6 upgrade issues. If you haven't seen that this bug got fixed, then please check whether this bug still exists in Mageia 6. If it does, then please change the Version (near the top, at the left) to "6". If you know it exists in Cauldron, then change Version to Cauldron. If you see it in both Cauldron and Mageia 6, then please set Version to Cauldron and add MGA6TOO on the Whiteboard. Thanks, Marja @ Jean-Louis: No reply, so closing as OLD since Mageia 5 is no longer maintained. ==> If you didn't reset your password after February 2018, then you'll need to reset it here https://identity.mageia.org/forgot_password to be able to log in and comment in this report. <== Resolution:
(none) =>
OLD |
I found a bug on starting : the sensor "temp6" of "ACPI" module gives all the time a very temperature : 90° . This temperature is not the right value . Sometimes the others temperatures are about 20° and this one is at maximum. I think you will find a problem with the sensors Manager on starting. May it try to access on ACPI module before that Manager is open. So in fact , the problem is simple : some variables /sys/class/thermal/cooling_device?/cur_state are not reseated to zero. By executing echo 0 > /sys/class/thermal/cooling_device?/cur_state Now on starting the Manager will consider that the temperatures are unknown and will not send an error signal. I added in the script /etc/rc.d/init.d/mandrake_evrytime echo 0 > /sys/class/thermal/cooling_device0/cur_state echo 0 > /sys/class/thermal/cooling_device1/cur_state ... etc .. Reproducible: Steps to Reproduce: