Forgot Password
smartctl --all -d sat /dev/sdb >/tmp/smartctl.out
smartctl.out (text/plain), 4.69 KB, created by
Herbert Poetzl
on 2011-05-31 18:55:29 CEST
(
hide
)
Description:
smartctl --all -d sat /dev/sdb >/tmp/smartctl.out
Filename:
MIME Type:
Creator:
Herbert Poetzl
Created:
2011-05-31 18:55:29 CEST
Size:
4.69 KB
patch
obsolete
>smartctl 5.40 2010-10-16 r3189 [x86_64-mageia-linux-gnu] (local build) >Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net > >=== START OF INFORMATION SECTION === >Model Family: SandForce Driven SSDs >Device Model: OCZ-AGILITY2 >Serial Number: OCZ-3L98TYHA25F7W62O >Firmware Version: 1.11 >User Capacity: 120,034,123,776 bytes >Device is: In smartctl database [for details use: -P show] >ATA Version is: 8 >ATA Standard is: ATA-8-ACS revision 6 >Local Time is: Tue May 31 18:53:36 2011 CEST >SMART support is: Available - device has SMART capability. >SMART support is: Enabled > >=== START OF READ SMART DATA SECTION === >SMART overall-health self-assessment test result: PASSED > >General SMART Values: >Offline data collection status: (0x00) Offline data collection activity > was never started. > Auto Offline Data Collection: Disabled. >Self-test execution status: ( 0) The previous self-test routine completed > without error or no self-test has ever > been run. >Total time to complete Offline >data collection: ( 0) seconds. >Offline data collection >capabilities: (0x7f) SMART execute Offline immediate. > Auto Offline data collection on/off support. > Abort Offline collection upon new > command. > Offline surface scan supported. > Self-test supported. > Conveyance Self-test supported. > Selective Self-test supported. >SMART capabilities: (0x0003) Saves SMART data before entering > power-saving mode. > Supports SMART auto save timer. >Error logging capability: (0x01) Error logging supported. > General Purpose Logging supported. >Short self-test routine >recommended polling time: ( 1) minutes. >Extended self-test routine >recommended polling time: ( 48) minutes. >Conveyance self-test routine >recommended polling time: ( 2) minutes. >SCT capabilities: (0x003d) SCT Status supported. > SCT Error Recovery Control supported. > SCT Feature Control supported. > SCT Data Table supported. > >SMART Attributes Data Structure revision number: 10 >Vendor Specific SMART Attributes with Thresholds: >ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE > 1 Raw_Read_Error_Rate 0x000f 120 120 050 Pre-fail Always - 0/0 > 5 Retired_Block_Count 0x0033 097 097 003 Pre-fail Always - 576 > 9 Power_On_Hours_and_Msec 0x0032 100 100 000 Old_age Always - 47h+50m+24.830s > 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 17 >171 Program_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 >172 Erase_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 >174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 9 >177 Wear_Range_Delta 0x0000 000 000 --- Old_age Offline - 0 >181 Program_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 >182 Erase_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 >187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 >194 Temperature_Celsius 0x0022 000 000 000 Old_age Always - 0 >195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/0 >196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0 >231 SSD_Life_Left 0x0013 095 095 010 Pre-fail Always - 1 >233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 0 >234 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 0 >241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 0 >242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 0 > >Warning! SMART ATA Error Log Structure error: invalid SMART checksum. >SMART Error Log Version: 39 >No Errors Logged > >Warning! SMART Self-Test Log Structure error: invalid SMART checksum. >SMART Self-test log structure revision number 41471 >Warning: ATA Specification requires self-test log structure revision number = 1 >No self-tests have been logged. [To run self-tests, use: smartctl -t] > > >SMART Selective self-test log data structure revision number 1 > SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS > 1 0 0 Not_testing > 2 0 0 Not_testing > 3 0 0 Not_testing > 4 0 0 Not_testing > 5 0 0 Not_testing >Selective self-test flags (0x0): > After scanning selected spans, do NOT read-scan remainder of disk. >If Selective self-test is pending on power-up, resume after 0 minute delay. >
smartctl 5.40 2010-10-16 r3189 [x86_64-mageia-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SandForce Driven SSDs Device Model: OCZ-AGILITY2 Serial Number: OCZ-3L98TYHA25F7W62O Firmware Version: 1.11 User Capacity: 120,034,123,776 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Tue May 31 18:53:36 2011 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 120 120 050 Pre-fail Always - 0/0 5 Retired_Block_Count 0x0033 097 097 003 Pre-fail Always - 576 9 Power_On_Hours_and_Msec 0x0032 100 100 000 Old_age Always - 47h+50m+24.830s 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 17 171 Program_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 172 Erase_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 9 177 Wear_Range_Delta 0x0000 000 000 --- Old_age Offline - 0 181 Program_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 182 Erase_Fail_Count 0x0000 000 000 000 Old_age Offline - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 000 000 000 Old_age Always - 0 195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/0 196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0 231 SSD_Life_Left 0x0013 095 095 010 Pre-fail Always - 1 233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 0 234 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 0 241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 0 242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 0 Warning! SMART ATA Error Log Structure error: invalid SMART checksum. SMART Error Log Version: 39 No Errors Logged Warning! SMART Self-Test Log Structure error: invalid SMART checksum. SMART Self-test log structure revision number 41471 Warning: ATA Specification requires self-test log structure revision number = 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
View Attachment As Raw
Actions:
View
Attachments on
bug 1504
: 499