Mageia Bugzilla – Attachment 3888 Details for
Bug 9084
Wrong default screen resolution on Thinkpad T42p 1600x1200 installer and Live
Home
|
New
|
Browse
|
Search
|
[?]
|
Reports
|
Requests
|
Help
|
Log In
[x]
|
New Account
|
Forgot Password
Output of # monitor-edid -v --try-in-console
monitor-edid-v--try-in-console.txt (text/plain), 931 bytes, created by
Morgan Leijström
on 2013-05-05 00:37:22 CEST
(
hide
)
Description:
Output of # monitor-edid -v --try-in-console
Filename:
MIME Type:
Creator:
Morgan Leijström
Created:
2013-05-05 00:37:22 CEST
Size:
931 bytes
patch
obsolete
>[root@speedstick ~]# monitor-edid -v --try-in-console >probing EDID using VBE (port 0) >VBE version: 2.0, oem version = 1.0 >Memory: 131008k >OEM name: ATI MOBILITY RADEON 9600 >Vendor name: ATI Technologies Inc. >Product name: GL10 >Product revision: 01.00 >Port 0: > DDC1 not supported > DDC2 not supported > Screen not blanked during data transfer > Time to transfer one EDID block: 2 sec (rounded up) >DDC (0x4f15:00): DDC not supported, not continuing >probing EDID using VBE (port 1) >Port 1: > DDC1 not supported > DDC2 not supported > Screen not blanked during data transfer > Time to transfer one EDID block: 2 sec (rounded up) >DDC (0x4f15:00): DDC not supported, not continuing >probing EDID using VBE (port 2) >Port 2: > DDC1 not supported > DDC2 not supported > Screen not blanked during data transfer > Time to transfer one EDID block: 2 sec (rounded up) >DDC (0x4f15:00): DDC not supported, not continuing >[root@speedstick ~]#
[root@speedstick ~]# monitor-edid -v --try-in-console probing EDID using VBE (port 0) VBE version: 2.0, oem version = 1.0 Memory: 131008k OEM name: ATI MOBILITY RADEON 9600 Vendor name: ATI Technologies Inc. Product name: GL10 Product revision: 01.00 Port 0: DDC1 not supported DDC2 not supported Screen not blanked during data transfer Time to transfer one EDID block: 2 sec (rounded up) DDC (0x4f15:00): DDC not supported, not continuing probing EDID using VBE (port 1) Port 1: DDC1 not supported DDC2 not supported Screen not blanked during data transfer Time to transfer one EDID block: 2 sec (rounded up) DDC (0x4f15:00): DDC not supported, not continuing probing EDID using VBE (port 2) Port 2: DDC1 not supported DDC2 not supported Screen not blanked during data transfer Time to transfer one EDID block: 2 sec (rounded up) DDC (0x4f15:00): DDC not supported, not continuing [root@speedstick ~]#
View Attachment As Raw
Actions:
View
Attachments on
bug 9084
:
3520
| 3888 |
3889
|
7055
|
7056