Mageia Bugzilla – Attachment 11402 Details for
Bug 25859
Error with a SSD PNY
Home
|
New
|
Browse
|
Search
|
[?]
|
Reports
|
Requests
|
Help
|
Log In
[x]
|
New Account
|
Forgot Password
Full output of smartctl
smart-ssd-pny.txt (text/plain), 5.54 KB, created by
Pierre Jarillon
on 2019-12-13 00:25:35 CET
(
hide
)
Description:
Full output of smartctl
Filename:
MIME Type:
Creator:
Pierre Jarillon
Created:
2019-12-13 00:25:35 CET
Size:
5.54 KB
patch
obsolete
>smartctl 7.0 2018-12-30 r4883 [x86_64-linux-5.3.13-desktop-2.mga7] (local build) >Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org > >=== START OF INFORMATION SECTION === >Device Model: PNY CS900 240GB SSD >Serial Number: PNY0719000352010883A >LU WWN Device Id: 5 f8db4c 07190883a >Firmware Version: CS900613 >User Capacity: 240â¯057â¯409â¯536 bytes [240 GB] >Sector Size: 512 bytes logical/physical >Rotation Rate: Solid State Device >Form Factor: 2.5 inches >Device is: Not in smartctl database [for details use: -P showall] >ATA Version is: ACS-4 (minor revision not indicated) >SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s) >Local Time is: Fri Dec 13 00:20:04 2019 CET >SMART support is: Available - device has SMART capability. >SMART support is: Enabled > >=== START OF READ SMART DATA SECTION === >SMART overall-health self-assessment test result: PASSED > >General SMART Values: >Offline data collection status: (0x00) Offline data collection activity > was never started. > Auto Offline Data Collection: Disabled. >Self-test execution status: ( 0) The previous self-test routine completed > without error or no self-test has ever > been run. >Total time to complete Offline >data collection: (65535) seconds. >Offline data collection >capabilities: (0x79) SMART execute Offline immediate. > No Auto Offline data collection support. > Suspend Offline collection upon new > command. > Offline surface scan supported. > Self-test supported. > Conveyance Self-test supported. > Selective Self-test supported. >SMART capabilities: (0x0003) Saves SMART data before entering > power-saving mode. > Supports SMART auto save timer. >Error logging capability: (0x01) Error logging supported. > General Purpose Logging supported. >Short self-test routine >recommended polling time: ( 2) minutes. >Extended self-test routine >recommended polling time: ( 30) minutes. >Conveyance self-test routine >recommended polling time: ( 6) minutes. > >SMART Attributes Data Structure revision number: 16 >Vendor Specific SMART Attributes with Thresholds: >ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE > 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 > 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 6052 > 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 5 >168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 >170 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 63 >173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 720927 >192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 1 >194 Temperature_Celsius 0x0023 067 067 000 Pre-fail Always - 33 (Min/Max 33/33) >218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0 >231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 99 >241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 1221 > >SMART Error Log Version: 1 >No Errors Logged > >SMART Self-test log structure revision number 1 >Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error ># 1 Extended offline Completed without error 00% 5912 - ># 2 Extended offline Completed without error 00% 5743 - ># 3 Extended offline Completed without error 00% 5576 - ># 4 Extended offline Completed without error 00% 5408 - ># 5 Extended offline Completed without error 00% 5240 - ># 6 Extended offline Completed without error 00% 5072 - ># 7 Extended offline Completed without error 00% 4903 - ># 8 Extended offline Completed without error 00% 4735 - ># 9 Extended offline Completed without error 00% 4566 - >#10 Extended offline Completed without error 00% 4399 - >#11 Extended offline Completed without error 00% 4230 - >#12 Extended offline Completed without error 00% 4063 - >#13 Extended offline Completed without error 00% 3895 - >#14 Extended offline Completed without error 00% 3726 - >#15 Extended offline Completed without error 00% 3558 - >#16 Extended offline Completed without error 00% 3390 - >#17 Extended offline Completed without error 00% 3222 - >#18 Extended offline Completed without error 00% 3054 - >#19 Extended offline Completed without error 00% 2886 - >#20 Extended offline Completed without error 00% 2719 - >#21 Extended offline Completed without error 00% 2550 - > >SMART Selective self-test log data structure revision number 0 >Note: revision number not 1 implies that no selective self-test has ever been run > SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS > 1 0 0 Not_testing > 2 0 0 Not_testing > 3 0 0 Not_testing > 4 0 0 Not_testing > 5 0 0 Not_testing >Selective self-test flags (0x0): > After scanning selected spans, do NOT read-scan remainder of disk. >If Selective self-test is pending on power-up, resume after 0 minute delay. >
smartctl 7.0 2018-12-30 r4883 [x86_64-linux-5.3.13-desktop-2.mga7] (local build) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: PNY CS900 240GB SSD Serial Number: PNY0719000352010883A LU WWN Device Id: 5 f8db4c 07190883a Firmware Version: CS900613 User Capacity: 240â¯057â¯409â¯536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Fri Dec 13 00:20:04 2019 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (65535) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 6052 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 5 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 170 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 63 173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 720927 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 1 194 Temperature_Celsius 0x0023 067 067 000 Pre-fail Always - 33 (Min/Max 33/33) 218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0 231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 99 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 1221 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 5912 - # 2 Extended offline Completed without error 00% 5743 - # 3 Extended offline Completed without error 00% 5576 - # 4 Extended offline Completed without error 00% 5408 - # 5 Extended offline Completed without error 00% 5240 - # 6 Extended offline Completed without error 00% 5072 - # 7 Extended offline Completed without error 00% 4903 - # 8 Extended offline Completed without error 00% 4735 - # 9 Extended offline Completed without error 00% 4566 - #10 Extended offline Completed without error 00% 4399 - #11 Extended offline Completed without error 00% 4230 - #12 Extended offline Completed without error 00% 4063 - #13 Extended offline Completed without error 00% 3895 - #14 Extended offline Completed without error 00% 3726 - #15 Extended offline Completed without error 00% 3558 - #16 Extended offline Completed without error 00% 3390 - #17 Extended offline Completed without error 00% 3222 - #18 Extended offline Completed without error 00% 3054 - #19 Extended offline Completed without error 00% 2886 - #20 Extended offline Completed without error 00% 2719 - #21 Extended offline Completed without error 00% 2550 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
View Attachment As Raw
Actions:
View
Attachments on
bug 25859
:
11399
| 11402